Welcome to Changshu Longyu Chemical Equipment Co., Ltd.

More than 20 years of focus on R&D and production of chemical equipment

Provide I, II carbon steel and stainless steel pressure vessel solutions

Service Hotline:

0512-52093708

+ Wechat number:18626143580

Your location: Home > news > Industry News

What factors affect the heat transfer efficiency of tower kettle reboiler

Source:www.cnlongyu.cn      Release date: 2026-11-09
Information summary:The heat transfer efficiency of the tower kettle reboiler is determined by the total heat transfer coefficient, effective heat transfer temperature difference, and heat transfer area, and is also influenced by six major factors: boiling flow state, medium properties, structural design, operating conditions, fouling and corrosion, and heat source system
       The heat transfer efficiency of the tower kettle reboiler is determined by the total heat transfer coefficient, effective heat transfer temperature difference, and heat transfer area, and is also influenced by six major factors: boiling flow state, medium properties, structural design, operating conditions, fouling and corrosion, and heat source system
1、 Physical properties of the medium and boiling flow state (core internal factors)
1. Physical property parameters of the medium
The boiling point, latent heat of vaporization, viscosity, density, surface tension, and thermal conductivity of the medium directly determine the boiling heat transfer intensity. The liquid film of high viscosity materials updates slowly, making it difficult for bubbles to detach, and the boiling heat transfer coefficient significantly decreases; Medium bubbles with high surface tension are not easy to precipitate and are prone to forming local gas films; Materials containing heavy components, colloids, and thermosensitive substances are prone to adhere to the tube wall, leading to continuous deterioration of heat transfer.
2. Boiling flow regime zoning
Nucleus boiling: continuous generation and detachment of bubbles, strong disturbance, high heat transfer coefficient, making it a better operating range for reboiler;
Transition boiling: high heat flux, bubble coalescence forming intermittent gas film, rapid decrease in heat transfer coefficient, and large temperature fluctuations;
Membrane boiling: The tube wall is enveloped by a continuous steam film, resulting in poor steam thermal conductivity and rapid deterioration of heat transfer. The tube wall is overheated, making it highly susceptible to coking, dry wall, and damage to the tube bundle.
3. Vaporization rate and cycle conditions
The thermosiphon reboiler is highly sensitive to vaporization rate. Low vaporization rate and insufficient two-phase disturbance; The vaporization rate is too high, the proportion of gas phase is too large, the circulation flow rate decreases, the pipe wall is short of liquid, and there are local dry walls. A low circulation ratio can cause insufficient liquid phase renewal inside the tube, resulting in a decrease in the average heat transfer coefficient.
2、 Operating process conditions
1. Tower pressure and static pressure boiling point increase
The pressure of the tower kettle changes the saturation temperature of the material, directly altering the effective heat transfer temperature difference; The static pressure of the liquid column inside the vertical thermosiphon reboiler tube bundle will increase the boiling point of the bottom material, reducing the actual heat transfer temperature difference. This effect is particularly prominent under vacuum distillation conditions.
2. Tower kettle liquid level
The liquid level directly affects the driving force of the thermosiphon: if the liquid level is too low, the static pressure head is insufficient, the circulating flow rate is insufficient, and the heat transfer deteriorates; If the liquid level is too high, the proportion of gas phase at the outlet of the tube bundle will be reduced, the circulation ratio will decrease, and the boiling heat transfer effect will also be reduced.
3. Heat load and heat source parameters
Fluctuations in temperature, flow rate, and pressure on the heat source side (steam/thermal oil/hot water) can alter the heat transfer temperature difference. If the temperature of the heat source is too high, it is easy to break through the upper limit of nucleate boiling and enter film boiling; The temperature of the heat source is too low, the overall temperature difference is insufficient, and the equipment output cannot reach the design value.
4. Changes in material composition
Fluctuations in feed components, accumulation of heavy components, and escape of light components can alter the saturation temperature, viscosity, and foaming characteristics of the kettle liquid; The foaming system is easy to form a foam layer, which reduces the effective liquid circulation and makes heat transfer unstable.
3、 Equipment Structure and Hydraulic Design
1. Type differences
The flow field structures of vertical thermosiphon, horizontal thermosiphon, kettle type, forced circulation, and falling film reboiler are different. The falling film type requires high requirements for uniform distribution of liquid film, and the distributor bias and uneven liquid distribution directly cause local dry walls; The gas phase space of the kettle reboiler is large, the boiling disturbance is weak, and the heat transfer coefficient is usually lower than that of the vertical thermosiphon.
2. Parameters of heat exchange tube bundle
The diameter, length, spacing, bundle arrangement, and baffle/support structure affect the flow velocity and two-phase distribution. Small tube diameter is conducive to bubble disturbance; Excessive tube bundle can lead to liquid shortage and dry wall in the upper part; Unreasonable baffle structure can cause flow field deviation and dead zone.
3. Import and export pipelines and elevation design
The diameter, length, number of bends, and elevation difference of the ascending and descending pipes determine the circulating resistance. Excessive pipeline resistance leads to a decrease in circulating flow rate, low liquid phase flow velocity inside the pipeline, and a decrease in heat transfer efficiency; Unreasonable pipeline layout can induce cyclic pulsation and surge.
4. Cloth, foam and internal components
Blockage or bias in the liquid distributor and redistributor of the falling film reboiler are common causes of heat transfer failure in falling film conditions; Unreasonable baffle and guide structure inside the kettle reboiler can cause liquid phase reflux short circuit.
4、 Working conditions on the heat source side (shell side/tube side heat source)
1. Saturated steam heat source
Non condensable gases (air, inert gas) continuously accumulate in steam, and the thermal conductivity of non condensable gases is low. They will form a gas film on the heat exchange wall, greatly reducing the heat transfer efficiency, which is a common cause of heat transfer attenuation in steam type reboiler;
2. Discharge status of condensate
Failure of the steam trap and poor drainage of condensate, resulting in accumulation of liquid in the shell side and flooding of the pipes. The effective heat exchange area is submerged by the condensate, and the available heat exchange area continues to decrease;
3. Heat medium oil/hot water heat source
Insufficient heat medium flow rate, low flow velocity, coking and scaling on the heat medium side, and decreased heat transfer coefficient on the heat medium side have become bottlenecks in heat transfer.
5、 Dirt, deposition, corrosion, and surface condition
1. Thermal resistance of dirt
The salts, colloids, polymers, tar, and catalyst particles in the kettle liquid will deposit on the wall of the heat exchange tube, forming a fouling layer. The fouling has a low thermal conductivity and increases the additional thermal resistance; The thicker the dirt, the lower the heat transfer efficiency.
2. Corrosion and surface roughness
Uniform corrosion, pitting corrosion, and erosion corrosion will change the surface roughness of the pipe wall: moderate roughness is conducive to boiling nucleation, but severe corrosion and loose corrosion products will adhere and form a corrosion scale layer, increasing thermal resistance; Localized corrosion thinning generally does not directly affect heat transfer, but it can pose a risk of leakage.
3. Coking and polymerization of pipe wall
Thermal sensitive materials stay on high-temperature walls for a long time, leading to thermal degradation, polymerization, and coking. The coke layer is dense, with high thermal resistance, and conventional cleaning is difficult.